PLL OPERATION CONSIDERATIONS

9.4PLL OPERATION CONSIDERATIONS

The following paragraphs discuss PLL operation considerations.

9.4.1Operating Frequency

The operating frequency of the chip is governed by the frequency control bits in the PLL control register as follows:

FCHIP =

FEXT MF

=

Fvco

----------DF-----------------

---DF----------

where: DF is the division factor defined by the DF0-DF3 bits

FCHIP is the chip operating frequency

FEXT is the external input frequency to the chip at the EXTAL pin

FVCO is the output frequency of the VCO

MF is the multiplication factor defined by the MF0-MF11 bits

The chip frequency is derived from the output of the low power divider. If the low power divider is bypassed, the equation is the same but the division factor should be assumed to be equal to one.

9.4.2Hardware Reset

Hardware reset causes the initialization of the PLL. The following considerations apply:

1.The MF0-MF11 bits in the PCTL register are set to their pre-determined hard- ware reset value. The DF0-DF3 bits and the Chip Clock Source bit in the PCTL register are cleared. This causes the chip clock frequency to be equal to the external input frequency (EXTAL) multiplied by the multiplication factor defined by MF0-MF11.

2.During hardware reset assertion, the PINIT pin value is written into the PEN bit in the PCTL register. If the PINIT pin is asserted (setting PEN), the PLL acquires the proper phase/frequency. While hardware reset is asserted, the internal chip clock will be driven by the EXTAL pin until the PLL achieves lock (if enabled). If the PINIT pin is deasserted during hardware reset assertion, the PEN bit is cleared, the PLL is deactivated and the internal chip clock is driven by the EXTAL pin.

3.PLOCK is a reliable indicator of the PLL lock state only after exiting the hard- ware reset state.

MOTOROLA

PLL CLOCK OSCILLATOR

9 - 11