INSTRUCTION DESCRIPTIONS

AND

Logical AND

Instruction Format:

AND S,D

Opcode:

AND

 

23

 

8

7

4

3

0

 

 

 

 

 

 

 

 

 

 

 

 

DATA BUS MOVE FIELD

 

0 1 J J

 

d

1 1 0

 

 

 

 

 

 

 

 

 

 

OPTIONAL EFFECTIVE ADDRESS EXTENSION

Instruction Fields:

 

S

J J

D d

X0

0 0

A 0 (only A1 is changed)

X1

1 0

B 1 (only B1 is changed)

Y0

0 1

 

Y1

1 1

 

Timing: 2+mv oscillator clock cycles

Memory: 1+mv program words

MOTOROLA

INSTRUCTION SET DETAILS

A - 33

Page 302
Image 302