Chapter 8: Hardware installation procedures 125

Installing the Application Module

The following procedure for installing the Application Module is only one of a series of procedures you should perform to install an Application Module. The series is shown in Table 12 in Chapter 5, ÒHardware installation overview.Ó Ensure that you have completed steps 1 through 5 in Table 12 before you start the following procedure.

!

CAUTION

Risk of personal injury

Ensure that the circuit breaker of the Application Module is in the off position.

Be careful when installing an Application Module because it is heavy. This is usually a two-person job.

You can install an Application Module in either side of an AEM (Application Equipment Module). Follow these steps:

1Hold the Application Module by the bar on the top and align the module with the guides at the top and bottom of the cage. Slowly slide the unit into the AEM.

2Tighten the four screws on the front of the module.

3Position the subpanel, universal I/O panel, or generic I/O panel (as supplied) at the rear of the module. Tighten or reinstall the screws that secure the panel.

4Attach the orange logic-return ground wire to the screw on the terminal block at the bottom of the AEM.

5Connect the yellow and gray cable from the power sense card to the appropriate plug on the power monitor. If the module is on the right side of the AEM (from the rear view), the cable connects to P1 on the power monitor. If the module is on the left side, the cable connects to P2.

Note: A connector housing surrounds the pins on the P1 and P2 connectors. Make sure you center the cable connector on the pins within the housing.

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 143