Meridian America Link/Customer Controlled Routing manual L0-1

Models: Link/Customer Controlled Routing

1 595
Download 595 pages 8.52 Kb
Page 208
Image 208

190Chapter 9: Meridian Link/CCR interface cabling

8Move cable end H-3 from slot position L8-1 to slot position L7-3.

9Remove cable K from the backplane and connect cable ends K-1, K-2, and K-3 to slot positions L8-1, L8-2, and L8-3.

10Add cable L to the I/O panel by connecting cable ends L-1, L-2, and L-3 to slot positions L9-1, L9-2, and L9-3.

The backplane cabling should now be as shown in Table 65 and Figure 50. All slots are now ready to receive an IPE Module.

Table 65 lists cable connections for a fully expanded configuration. Figure 50 shows the backplane slots in a fully expanded configuration.

Table 65

NT8D11 cable connections (fully expanded configuration)

I/O panel connector

Backplane cable

Backplane slot

port

connector

position

 

 

 

A

A-1

L0-1

 

A-2

L0-2

 

A-3

L0-3

 

 

 

B

B-1

L1-1

 

B-2

L1-2

 

B-3

L1-3

 

 

 

C

C-1

L2-1

 

C-2

L2-2

 

C-3

L2-3

 

 

 

D (new cable)

D-1

L3-1

 

D-2

L3-2

 

D-3

L3-3

 

 

 

E

E-1

L4-1

 

E-2

L4-2

 

E-3

L4-3

 

 

 

F

F-1

L5-1

 

F-2

L5-2

 

F-3

L5-3

 

 

 

Ñ continued Ñ