Meridian America Link/Customer Controlled Routing manual Meridian Link/CCR interface cabling

Models: Link/Customer Controlled Routing

1 595
Download 595 pages 8.52 Kb
Page 178
Image 178

160Chapter 9: Meridian Link/CCR interface cabling

Table 47

NT1R03BA 50-pin four-port cable pinout (IPE Module)

From

To

Port

Signal

From

To

Port

Signal

DB-50

DB-25

 

name

DB-50

DB-25

 

name

1

7

2

GND2

26

8

2

DCD2

2

2

2

TXD2

27

3

2

RXD2

3

4

2

RTS2

28

5

2

CTS2

4

6

2

DSR2

29

20

2

DTR2

5

7

4

GND4

30

8

4

DCD4

6

2

4

TXD4

31

3

4

RXD4

7

4

4

RTS4

32

5

4

CTS4

8

6

4

DSR4

33

20

4

DTR4

9

7

6

GND6

34

8

6

DCD6

10

2

6

TXD6

35

3

6

RXD6

11

4

6

RTS6

36

5

6

CTS6

12

6

6

DSR6

37

20

6

DTR6

13

15

6

TXCI6

38

17

6

RXCI6

14

22

6

RI6

39

24

6

TXCO6

15

7

8

GND8

40

8

8

DCD8

16

2

8

TXD8

41

3

8

RXD8

17

4

8

RTS8

42

5

8

CTS8

18

6

8

DSR8

43

20

8

DTR8

19

15

8

TXCI8

44

17

8

RXCI8

20

22

8

RI8

45

24

8

TXCO8

21

 

 

NC

46

 

 

NC

22

 

 

NC

47

 

 

NC

23

 

 

NC

48

 

 

NC

24

 

 

NC

49

 

 

NC

25

 

FGND

FGND

50

 

FGND

FGND

553-3202-210 Standard October 1998

Page 178
Image 178
Meridian America Link/Customer Controlled Routing manual Meridian Link/CCR interface cabling