206 Chapter 9: Meridian Link/CCR interface cabling
553-3202-210 Standard October 1998
Figure 54
NT8D11 backplane cable designations (segment 0 has been rerouted)
Segment 3 Segment 2 Segment 1 Segment 0
S-1
S-2
L16L15 L14 L13 L12
T-2
T-3
S-3
T-1
R-1
R-2
R-3
M-2 L-3 L-1 K-1
M-3 M-1 L-2 K-2
K-3
S-1
L11L10 L9 L8
Shroud Row
1
2
3
L7 L6 L5 L4 L3
E-1
E-2
E-3
F-1
F-2
F-3
G-1
G-2
G-3
L2 L1 L0
A-1
A-2
A-3
B-1
B-2
B-3
D-1
D-2
D-3
S-2
NT8D37 backplane cable rerouting for segment 1Ñtoaccommodate the IPE Module in PE slots 4Ð7
1Leave cable E as is in slot position L4.
2Remove cable G from the backplane and connect cable ends G-1,
G-2, and G-3 to slot positions L7-1, L7-2, and L7-3.
3Move the G connector on the I/O panel to position H. Now the cable
designation is changed from G to H.
!
CAUTION
Risk of hardware damage
With this cable rerouting, the IPE Module can only beused in PE slots 4Ð7. Also, when the IPE Module is notin PE slots 4Ð7, PE slot 6 should not be used at all.Note: Reroute the cable only in the segment where the IPE Module isgoing to be installed. Do not reroute the cable in other segments.