Chapter 14: Software installation, upgrade, and update procedures 431

Procedure 6: Load the operating system tape on an IPE Module or an Application Module with an MVME167 card (continued)

Note: If you changed or reentered any values in Figure 173, you will see two additional prompts, to which you should respond as shown in the following figure.

Figure 174

Additional prompts (IPE Module)

Update Non-Volatile RAM (Y/N)?

Reset Local System (CPU) (Y/N)?

y<cr>

y <cr>

5At the Ò167-Diag>Ó prompt, type env and press [Return].

The environment prompts appear. Answer them as indicated in the following figures. Then go to step 6.

If you make a mistake, quit the process by entering a period (.) at a prompt and answering n for the last two questions (Update Non- Volatile RAM/Reset Local System). This brings you back to the Ò167-Diag>Ó prompt. Then type env;d and press [Return] to undo the mistakes you made and bring back the original default values.

Note: At the ÒAuto Boot Controller LUN=00?Ó prompt, type a period and press [Return] to bypass additional prompts that do not need to be changed.

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 449
Image 449
Meridian America Link/Customer Controlled Routing manual At the Ò167-DiagÓ prompt, type env and press Return