Chapter 9: Meridian Link/CCR interface cabling 181

4Connect the NT1R03CA extension cable that is connected to the NT1R03BA octopus cable to the appropriate connector as shown in Tables 58 and 59. For example, if the IPE module is located in slots 2, 3, and 4, connect the extension cable to connector J2.

Table 58

Option 11 IPE ModuleÑNTIR03BA/NT1R03CA cable connection (main cabinet)

Slots occupied by the

Connect NT1R03BA/NT1R03CA

IPE Module

cables to connector port

 

 

2, 3, 4

J2

 

 

3, 4, 5

J3

 

 

4, 5, 6

J4

 

 

5, 6, 7

J5

 

 

6, 7, 8

J6

 

 

7, 8, 9

J7

 

 

Table 59

Option 11 IPE ModuleÑNT1R03BA/NT1R03CA cable connections (expansion cabinet)

Slots occupied by the

Connect NT1R03BA/NT1R03CA

IPE Module

cables to connector port

 

 

11, 12, 13

J11

 

 

12, 13, 14

J12

 

 

13, 14, 15

J13

 

 

14, 15, 16

J14

 

 

15, 16, 17

J15

 

 

16, 17, 18

J16

 

 

17, 18, 19

J17

 

 

18, 19, 20

J18

 

 

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 199
Image 199
Meridian America Link/Customer Controlled Routing manual