Chapter 8: Hardware installation procedures 131

Table 31

MVME333-2 XCC card jumper settings

Block

Jumper setting

 

 

K1

2 and 4, 6 and 8, 10 and 12, 13Ð14, 15Ð16, 23Ð24

K2

none

K3

1Ð2, 5Ð6, 7Ð8, 9Ð10

K4

none

K5

1Ð2, 3Ð4

K6

5Ð6

K7

5Ð6

K8

none

K9

1Ð2

 

 

6Replace the MVME333-2 XCC card and replace the screws at the top and bottom of the faceplate.

7If you are checking the option settings for an Application Module installed on the left side of the AEM, go to step 5. If the Application Module is preinstalled on the right side of the AEM, remove it as follows:

¥If you have an I/O subpanel, loosen the five spring-loaded screws that hold the I/O subpanel to the I/O assembly of the AEM. Gently set the panel in the back of the Application Module so the cables do not come in contact with the edges of the AEM.

¥If you have a universal I/O panel or a generic I/O panel, remove the screws at the edges of the I/O panel. Gently set the panel in the back of the Application Module.

¥Detach the orange logic-return ground wire that is screwed to the terminal block at the bottom of the AEM.

¥Unplug the yellow and gray cable (NT7D52AA) that connects the power sense card to the power monitor.