538Chapter 19: Single Terminal Access

8Configure the MSDL port for STA. Define the port and its characteristics by responding to the following prompts in LD 17. Substitute the device number where ÒxÓ appears in the Response column.

Table 147

LD 17ÑConfigure MSDL port

Prompt

Response

Comment

REQ

CHG

Create or change information in the database

TYPE

CFN

Configuration record data block

ADAN

NEW TTY x

Add TTY with a logical ID x (0-15). The TTY

 

 

number must be the same as the DNUM of

 

 

the MSDL.

CTYP

MSDL

Card type is MSDL (automatic response)

GRP

0

Network Group Number (this prompt appears

 

 

only for Option 81 systems)

DNUM

x

Device number; same as TTY (automatic

 

 

response)

PORT

0

Admin port number (automatic response)

DES

STA_ADMIN

Designate port 0 for the STA terminal.

BPS

9600

Baud rate

PARY

NONE

Parity type

STOP

1

Number of stop bits

BITL

8

Data bit length

PARM

RS-232 DCE

Interface and transmission mode

FUNC

ABD FCL LME

MSDL card functions

USER

MTC SCH BUG

Output message types

XSM

NO

SDI port for the system monitor

TTYLOG

<cr>

Log buffer size

<cr> through remaining prompts

553-3202-210 Standard October 1998