412Chapter 14: Software installation, upgrade, and update procedures

Procedure 4: Power down the IPE Module or the Application Module (continued)

5If software users are logged in, a list appears. Whether a list appears or not, you are prompted to start an express powerdown. If no list appears, or if you do not wish to alert all logged-in users, type y and press [Return].

If you wish to alert all users currently logged into the system of the powerdown, type n and press [Return]. If you do, you are prompted to enter the number of seconds the system should wait after the warning message. Type the number of seconds that will allow the users to save their work and log off. Then press [Return].

The information shown in Figure 142 appears on the screen.

Figure 142

Shutdown message screen

Shutdown started.

Broadcast Message from root (console) on sysV68

THE SYSTEM IS BEING SHUTDOWN NOW! ! !

Log off now or risk you files being damaged.

INIT: New run level: 0

The system is coming down. Please wait.

System services are now being stopped.

Terminating applications

Releasing Communication Resources...

The system is down.

NOTICE: System Halt Requested (0)

NOTICE: System secured for powering down.

6When the system confirms that it is secured for powering down, set the Application Module circuit breaker to OFF or press the power pushbutton on the IPE Module.

7If your system uses an Application Module with an MVME147 card, go to Procedure 5.

If your system uses an IPE Module or an Application Module with an MVME167 card, go to Procedure 6.

553-3202-210 Standard October 1998

Page 430
Image 430
Meridian America Link/Customer Controlled Routing manual Shutdown message screen, System is Being Shutdown NOW