Chapter 12: Meridian 1 configuration for Meridian Link/CCR 299

Configure ESDI port (X11 Release 17)

The IPE Module or Application Module is connected to the Meridian 1 through a port on a QPC513 ESDI card (vintage G or later) or an NTAK02 SDI/DCH card (Option 11, IPE Module only). The port must have the AML identified (VSID 0Ð15). Define the ESDI port and its characteristics by responding to the following prompts in

LD 17.

Options 21Ð81 ESDI configuration

Table 106

LD 17ÑConfigure ESDI port (Options 21Ð81)

Prompt

Response

Comment

 

 

 

REQ

CHG

Create or change information in the

 

 

database

TYPE

CFN

Configuration record data block

PWD2

<cr>

 

ISDN

<cr>

 

PARM

YES

Change a parameter

NCR

26Ð2047,

Increment the current value by the value

 

5000

used for CSQI and CSQO. See those

 

 

prompts described later in this table.

 

 

Note: The Meridian 1 must be reinitialized if

 

 

NCR is changed.

CEQU

<cr>

 

OVLY

<cr>

 

IOTB

YES

Change I/O terminals or devices

HIST

<cr>

 

ADAN

NEW TTY x

Add ESDI on port x

ESDI

YES

Port is on an ESDI card

SYNC

YES

Synchronous mode

 

 

 

 

 

ÑcontinuedÑ

 

 

 

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 317
Image 317
Meridian America Link/Customer Controlled Routing manual Configure Esdi port X11 Release, Options 21Ð81 Esdi configuration