300 Chapter 12: Meridian 1 configuration for Meridian Link/CCR
553-3202-210 Standard October 1998
Table 106
LD 17ÑConfigure ESDI port (Options 21Ð81) (continued)
Prompt Response Comment
DUPX FULL Full duplex mode
BPS 19200 19,200 bps baud rate (19.2 kbps). (The
baud rate for link 0 of the Application Module
must also be set to 19,200 bps.)
CLOK INT Internal clock
IADR 3 Internal address for AML LAPB
RADR 1 Remote address for AML LAPB
LCTL YES Modify link control parameters
T1 4 Layer 2 retransmission timer in units of 0.5
seconds
T2 0 Layer 2 acknowledge timer in units of 0.5
seconds
T3 10 Layer 2 link set-up timer in units of 0.5
seconds (only for ESDI)
N1 128 Maximum I frame length in octet
N2 8 Maximum number of Layer 2 retransmission
K 1Ð(7) Maximum number of outstanding frames
Note: This number must match the value
set for Link 0 on the Meridian Link.
LTHR <cr>
USER CMS ESDI port is a Command and Status link
ADAN <cr>
VAS NEW Value Added Server Identifier (VAS ID)
VSID 0Ð15 VAS (AML) identifier
DLOP <cr>
ÑcontinuedÑ