300Chapter 12: Meridian 1 configuration for Meridian Link/CCR

Table 106

LD 17ÑConfigure ESDI port (Options 21Ð81) (continued)

Prompt

Response

Comment

 

 

 

DUPX

FULL

Full duplex mode

BPS

19200

19,200 bps baud rate (19.2 kbps). (The

 

 

baud rate for link 0 of the Application Module

 

 

must also be set to 19,200 bps.)

CLOK

INT

Internal clock

IADR

3

Internal address for AML LAPB

RADR

1

Remote address for AML LAPB

LCTL

YES

Modify link control parameters

T1

4

Layer 2 retransmission timer in units of 0.5

 

 

seconds

T2

0

Layer 2 acknowledge timer in units of 0.5

 

 

seconds

T3

10

Layer 2 link set-up timer in units of 0.5

 

 

seconds (only for ESDI)

N1

128

Maximum I frame length in octet

N2

8

Maximum number of Layer 2 retransmission

K

1Ð(7)

Maximum number of outstanding frames

 

 

Note: This number must match the value

 

 

set for Link 0 on the Meridian Link.

LTHR

<cr>

 

USER

CMS

ESDI port is a Command and Status link

ADAN

<cr>

 

VAS

NEW

Value Added Server Identifier (VAS ID)

VSID

0Ð15

VAS (AML) identifier

DLOP

<cr>

 

 

 

 

 

 

ÑcontinuedÑ

 

 

 

553-3202-210 Standard October 1998

Page 318
Image 318