130Chapter 8: Hardware installation procedures

If your Application Module does not have CCR activated, the MVME332XT(S) card may not be present. If so, skip steps 1Ð3 and begin at step 4.

1Remove the screws at the top and bottom of the MVME332XT(S) card faceplate.

2Pull the MVME332XT(S) card out of the Application Module. Check the switches as indicated in Tables 29 and 30.

Table 29

MVME332XT ACC card switch settings

 

 

 

 

Position

 

 

 

Switch

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

S1

on

off

off

off

off

on

on

on

S2

off

off

on

on

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 30

 

 

 

 

 

 

 

 

MVME332XT ACC card jumper settings

 

 

 

 

 

 

 

 

 

 

 

Block

 

 

 

Jumper setting

 

 

 

 

 

 

J1

1Ð2, 5Ð6, 7Ð9, 8Ð10, 11Ð12, 15Ð17

 

 

J4

1Ð2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3Replace the MVME332XT(S) card and replace the screws at the top and bottom of the faceplate.

4Remove the screws at the top and bottom of the MVME333-2 XCC card faceplate.

5Pull the MVME333-2 XCC card out of the Application Module. Check the switches as indicated in Table 31 and Figure 34.

553-3202-210 Standard October 1998

Page 148
Image 148
Meridian America Link/Customer Controlled Routing manual MVME332XT ACC card switch settings Position Switch