Chapter 11: Peripheral device cabling interface 279

USRobotics Sportster modem

The USRobotics Sportster (14.4) modem allows you to extend the distance between the IPE Module or the Application Module and any connected peripheral equipment.

The switch settings are shown in the following table.

Table 102

USRobotics Sportster switch settings

Switch setting

Position

Description

 

 

 

1

Up

DTR Normal

 

 

 

2

Up

Verbal result codes

 

 

 

3

Down

Display result codes

 

 

 

4

Up

Echo offline commands

 

 

 

5

Up

Auto answer

 

 

 

6

Up

Carrier detect normal

 

 

 

7

Down

Load factory defaults

 

 

 

8

Down

Smart mode

 

 

 

Note: When dialing up the system, you may need to send several <BREAK> commands from your remote end to the system in order to bring up the login prompt. The systemÕs baud rate may be different from the modem baud rate therefore sending the <BREAK> command causes the system to cycle through various baud rates. When the system reaches the correct baud rate, you will see the login prompt on your remote screen.

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 297
Image 297
Meridian America Link/Customer Controlled Routing manual USRobotics Sportster modem