198Chapter 9: Meridian Link/CCR interface cabling

NT8D37 backplane cable expansionÑsegment 0

With the cables located as shown in Table 67:

1Leave cable A as is in slot position L0.

2Move cable end B-3 from slot position L2-1 to slot position L1-3.

3Remove cable C from the backplane and connect cable ends C-1, C-2 and C-3 to slot positions L2-1, L2-2, and L2-3.

4Add cable D to the I/O panel by connecting cable ends D-1, D-2, and D-3 to slot positions L3-1, L3-2, and L3-3.

The IPE shelf is now ready to receive an IPE Module in slots 0Ð3.

NT8D37 backplane cable expansionÑsegment 1

1Leave cable E in slot position L4.

2Move cable end F-3 from slot position L6-1 to slot position L5-3.

3Remove cable G from the backplane and connect cable ends G-1, G-2, and G-3 to slot positions L6-1, L6-2, and L6-3.

4Add cable H to the I/O panel by connecting cable ends H-1, H-2, and H-3 to slot positions L7-1, L7-2, and L7-3.

The IPE shelf is now ready to receive an IPE Module in slots 4Ð7.

NT8D37 backplane cable expansionÑsegment 2

1Leave cable K in slot position L8.

2Move cable end L-3 from slot position L10-1 to slot position L9-3.

3Remove cable M from the backplane and connect cable ends M-1, M-2, and M-3 to slot positions L10-1, L10-2, and L10-3.

4Add cable N to the I/O panel by connecting cable ends N-1, N-2, and N-3 to slot positions L11-1, L11-2, and L11-3.

The IPE shelf is now ready to receive an IPE Module in slots 8Ð11.

553-3202-210 Standard October 1998

Page 216
Image 216
Meridian America Link/Customer Controlled Routing manual NT8D37 backplane cable expansionÑsegment