540Chapter 19: Single Terminal Access

Table 148

LD 17ÑConfigure MSDL port

Prompt

Response

Comment

REQ

CHG

Create or change information in the

 

 

database

TYPE

CFN

Configuration record data block

ADAN

NEW STA x

Add STA with a logical ID x (0-15)

TTY

0-15

Device number (MSDL SDI TTY)

 

 

Note: Use the same TTY number

 

 

you assigned to the ADAN prompt in

 

 

step 8.

CTYP

MSDL

Card type is MSDL (automatic

 

 

response)

GRP

0

Network Group Number (this prompt

 

 

only appears for Option 81 systems)

DNUM

0Ð15

Device number; same as TTY

 

 

(automatic response)

ADMIN_

0

Admin port number (automatic

PORT

 

response)

LANG

(ENG)

Language supported (automatic

 

 

response for Release 19)

ADDITIONAL

P1, P2, P3

The MSDL port(s) cabled to the SYS

PORTS*

 

CONS port

*If one of the ADDITIONAL PORTS must be deleted, type an ÒXÓ before the port number (for example, XP2).

12Verify the above configuration in LD 22.

13Access LD 48 and type ENL STA x to enable the STA port.

14Type STAT STA x to verify the status of the STA application.

Figure 301 shows STA 0 on port 0 (admin port) is enabled.