248Chapter 9: Meridian Link/CCR interface cabling

System console cabling (Application Module)

As shown in Figures 65Ð74, the system console connects to the MVME712 transition card at

¥J7 on the I/O subpanel

¥SYS CONS port on the universal I/O panel

¥card 1 conn 1 on the generic I/O panel

Use a customer-supplied cable (or an extra NT7D61) with a 9-pin female and 25-pin male connector from the console to the Application Module. Table 83 lists the pin assignments required for the cable.

Table 83

System console cable pinout

Meridian 1

Signal

AM (J7) 9-pin connector

 

 

 

2

TXD

3

3

RXD

2

4

RTS

7

5

CTS

8

6

DSR

6

7

LRTN

5

8

DCD

1

20

DTR

4

1

GND

9

 

 

 

553-3202-210 Standard October 1998