438Chapter 14: Software installation, upgrade, and update procedures

Procedure 6: Load the operating system tape on an IPE Module or an Application Module with an MVME167 card (continued)

Figure 185

BOS software management menu

The BOS (FE03.71) Software Management Menu

1

install

Install

FE03.71 BOS Software

2

upgrade

Upgrade

To FE03.71 BOS Software

---> Enter a number, a name, the initial part of name, or ? or <number>? for HELP, q to QUIT:

17At the software management menu, type 1 and press [Return] to install the software.

The BOS installation procedure begins.

Figure 186

BOS installation, phase 1

Phase 1. Identify Root And Usr File Systems Installation Disk Drive(s)

The BOS product supports root and usr file system installations

on the disk controllers listed below. The first column is the controllerÕs selection number, the second column is the name of the controller, and, the third column is a brief description of the controller. Identify

at the prompt the root file systemÕs installation disk controller type.

1

MVME147

The MVME147 CPU

Processor/SCSI Controller

2

MVME167

The MVME167 CPU

Processor/SCSI Controller

3

MVME323

The MVME323 ESDI Disk Controller

4

MVME327

The MVME327 SCSI

Bus Controller

5

MVME328

The MVME328 SCSI

Host Adapter

---> Enter a number, a name, the initial part of a name, or ? or <number>? for HELP, or q to QUIT [MVME167]:

18The system prompts you to select the disk controller. Whether you have an IPE Module or an Application Module, type 2 and press [Return] to select the MVME167 SBC card (this option supports both the IPE Module and the Application Module with an MVME167 card).

The system response is ÒSelected the ÔMVME167Õ controller type.Ó

553-3202-210 Standard October 1998

Page 456
Image 456
Meridian America Link/Customer Controlled Routing manual System response is ÒSelected the ÔMVME167Õ controller type.Ó