Chapter 14: Software installation, upgrade, and update procedures 421

Procedure 5: Load the operating system tape on an Application Module with an MVME147 card (continued)

20Type 1 and press [Return] to install the software.

The BOS installation procedure begins.

Figure 156

BOS installation, phase 1

BOS INSTALLATION PROCEDURE

Phase 1. Identify Root And Usr File Systems Installation Disk Drive(s)

The BOS product supports root and usr file system installations

on the disk controllers listed below. The first column is the controllerÕs selection number, the second column is the name of the controller, and, the third column is a brief description of the controller. Identify

at the prompt the root file systemÕs installation disk controller type.

1

MVME147

The MVME147 CPU

Processor/SCSI Controller

2

MVME167

The MVME167 CPU

Processor/SCSI Controller

3

MVME323

The MVME323 ESDI Disk Controller

4

MVME327

The MVME327 SCSI

Bus Controller

5

MVME328

The MVME328 SCSI

Host Adapter

---> Enter a number, a name, the initial part of a name, or ? or <number>? for HELP, or q to QUIT [MVME167]:

21When prompted to select the SBC card, type 1 and press [Return].

The system response is ÒSelected the ÔMVME147Õ controller type.Ó

Figure 157

Disk drive number prompt

---> Enter the root file systemÕs disk drive number (00, 10, 20, 30, ?, q) [00]:

22You are prompted to enter the root file systemÕs disk drive number. Press [Return] to select the default disk drive number (00).

The disk drive selection list appears.

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 439
Image 439
Meridian America Link/Customer Controlled Routing manual BOS installation, phase, Disk drive number prompt