Chapter 17: Hardware upgrade 521

Procedure 26: Upgrading the Application Module from an MVME147 card to an MVME167 card

1Complete Procedure 25: Hardware powerdown.

2Loosen the screws at the top and bottom of the card.

3Use the ejectors to unlock the card.

4Pull the MVME147 card out of the Application Module.

5Slide the MVME167 card into the Application Module. Firmly press the middle of the faceplate to seat the card.

6Tighten the screws on the faceplate of the replacement card.

7Restore power to the Application Module by setting the MPDU circuit breaker to ON (up).

The system reboots into the ÒConsole Login:Ó prompt.

8Complete Procedure 6: Load the operating system tape on an IPE Module or an Application Module with an MVME167 card.

9Complete Procedure 7: Reboot and go through setup.

10Complete Procedure 8: Load the application software from tape.

11Complete Procedure 9: Restore configuration files and data files from the backup tape.