Chapter 9: Meridian Link/CCR interface cabling 197

Figure 52

NT8D37 backplane cable designations (standard configuration)

 

 

 

 

 

 

 

 

Segment 3

 

 

Segment 2

 

 

 

 

 

Segment 1

 

 

 

Segment 0

 

 

 

 

 

 

 

 

L8

 

 

 

 

 

 

L7

 

L6

 

L5

 

L4

 

 

 

 

 

 

 

 

 

L0

 

 

 

 

 

L16 L15 L14 L13L12

L11 L10 L9

 

 

 

 

 

 

 

 

 

 

 

L3

 

 

L2

L1

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T-2

 

 

S-3

 

S--1

 

R-1

 

 

M-2

 

L-3

 

L-1

 

K-1

 

 

 

 

 

 

 

G-2

 

F-3

 

F-1

 

E-1

 

 

C-2

 

 

B-3

 

B-1

 

A-1

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T-3

 

 

T-1

 

S-2

 

R-2

 

 

M-3

 

M-1

 

L-2

 

K-2

 

 

 

 

 

 

 

G-3

 

G-1

 

F-2

 

E-2

 

 

C-3

 

 

C-1

 

B-2

 

A-2

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

R-3

 

 

 

 

 

 

 

 

K-3

 

 

 

 

 

 

 

 

 

 

 

 

 

E-3

 

 

 

 

 

 

 

 

 

A-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shroud Row

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cabling for each segment can be expanded using one NT8D81AA cable/filter assembly. Cabling for the entire backplane can be expanded using four NT8D81AA cable/filter assemblies.

If you do not have additional NT8D81AA cable/filter assemblies available, you can reroute the existing cables to accommodate the Meridian Link/CCR IPE Module in specific PE slots. For more information on this, refer to the NT8D37 backplane cable rerouting procedures (such as ÒNT8D37 backplane cable rerouting for segment 0Ñto accommodate the IPE Module in PE slots 0Ð3Ó) later in this section.

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 215
Image 215
Meridian America Link/Customer Controlled Routing Segment, NT8D37 backplane cable designations standard configuration