Chapter 12: Meridian 1 configuration for Meridian Link/CCR 301

Table 106

LD 17ÑConfigure ESDI port (Options 21Ð81) (continued)

Prompt

Response

Comment

 

 

 

CMS

x

ESDI port number for this AML. This must

 

 

be the same as the port number defined at

 

 

the ADAN prompt.

SECU

YES

Security for AML. Must be set to Yes.

INTL

4

Time interval (five-second increments) used

 

 

to determine overload conditions

MCNT

400

Message count threshold for number of

 

 

messages per time interval (from INTL)

CONF

DIR

Direct link for this AML configuration

CMS

<cr>

ESDI port number for CSL (0Ð15)

VSID

<cr>

 

VAS

<cr>

 

CSQI

(20)Ð255

Maximum call registers for AML input

 

 

queues

CSQO

(20)Ð255

Maximum call registers for AML output

 

 

queues

 

 

Set CSQI and CSQO equal to the number of

 

 

ACD agents or AST sets, or 50 whichever is

 

 

larger, but not more than 25 percent of the

 

 

total number of call registers (NCR prompt).

¥

 

Press [Return] until the REQ prompt

¥

 

appears

¥

 

 

REQ

END

Either change more configuration data or

 

 

exit the overlay, saving changes to the

 

 

configuration record.

 

 

 

 

 

Ñ end Ñ

 

 

 

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 319
Image 319