Chapter 12: Meridian 1 configuration for Meridian Link/CCR 297

¥A Meridian 1 with two modules (two Application Modules, or two IPE Modules, or one of each), one module with Meridian Link but not CCR activated, one module with CCR but not Meridian Link activated:

ÑVSID prompts (LD17) Use two VSID prompts to enter values to define two different VAS IDs to be associated with the two AMLs.

ÑAML prompts (LD17) Use two AML prompts to enter two ESDI or MSDL port numbers to be associated with the two VAS IDs.

ÑVSID prompt (LD15) Enter the value from the VSID prompt in LD17 associated with the AML connected to the module with Meridian Link activated.

ÑVSID prompt (LD23) Enter the value from the VSID prompt in LD17 associated with the AML connected to the module with CCR activated.

ÑHSID prompt (LD23) Enter the value from the VSID prompt in LD17 associated with the AML connected to the module with Meridian Link activated.

¥A Meridian 1 with a single IPE Module or Application Module with both Meridian Link and CCR activated:

ÑVSID prompt (LD17) Enter a value to define the VAS ID to be associated with the AML.

ÑAML prompt (LD17) Enter the ESDI or MSDL port number to be associated with the VAS ID.

ÑVSID prompt (LD15) Enter the value from the VSID prompt in LD17.

ÑVSID prompt (LD23) Enter the value from the VSID prompt in LD17.

ÑHSID prompt (LD23) Do not enter a value.

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Page 315
Image 315