Program 21 : Outgoing Call Setup
21-15 : Individual Trunk Group Routing for Extensions
1042 Programming Aspire Software Manual
21-15 : Individual Trunk Group Routing for Extensions
Description
Use Program 21-15 : Individual Trunk Group Route for Extensions to designate the alternate
trunk access route accessed when a user dials the Alternate Trunk Route Access Code. Refer to Pro-
gram 11-09-02 : Alternate Trunk Access Code when setting up alternate trunk codes. Turn to Pro-
gram 14-06 : Trunk Group Routing to set up the trunk routes. When entering data for this option,
enter the route number or 0 to prevent routing.
Input Data
Conditions
None
Feature Cross Reference
Central Ofce Calls, Placing
Level: Aspire S Aspire M/L/XL
IN • Available. • Available.
Extension Number Max. 8 digits
Item No. Day/Night Mode Route Table Number Default
01 Aspire S: 1-4
Aspire: 1-8 Aspire S: 0-8
Aspire: 0-100
(0 = no setting)
0