Maintenance
398 ◆Features Aspire Software Manual
Programming
System Maintenance
➻11-11-13 : Service Code Setup (for Setup/Entry Operation) - Display Language Selection
for Keyset
Define the service code to be used to change the language shown on display keysets (default:
178).
➻11-15-01 : Service Code Setup, Administrative (for Special Access) - Remote Maintenance
Set the service code used in the dial-up number when using the serial or USB port for PCPro
or WebPro (default: 830).
➻11-15-03 : Service Code Setup, Administrative (for Special Access) - Backup Data Save
This option will save the user’s soft key settings (extension’s programmed Call Forwards,
DND, etc.). It is recommended to use this feature before upgrading the system software.
➻90-03-01 : Save Data
Save the programmed data on the SRAM and Flash ROM to a compact flash memory card.
➻90-04-01 : Load Data
Load the saved system data from an inserted compact flash memory card to the SRAM and
Flash ROM in the system.
Note: Aspire S and Aspire Customer Databases Not Interchangeable!
The system will not be able to prevent an incorrect upload. It is important to make
sure you only load data saved from an Aspire S to an Aspire S system and data
saved from an Aspire to an Aspire system.
➻90-05-01 : Slot Control
Reset (Menu 1) or delete/uninstall (Menu 2) circuit boards (slots 1-16) as needed through
either telephone programming or WebPro access.
➻90-06-01 : Trunk Control
Busy Out (0) lets you block a PCB from placing outgoing calls (just like placing the PCB
switch down). Once busied out, none of the ports on the PCB can be used for new calls. Exist-
ing calls, however, are not disconnected. Release the Busy Out state by entering “1” for the
trunk. This option is available through telephone programming, PCPro or WebPro access.
➻90-07-01 : Extension Control
Perform a hardware (1) or software (2) reset on a particular extension as needed through either
telephone programming or WebPro access.
➻90-08-01 : System Reset
Perform a system reset as needed through either telephone programming or WebPro access.
➻90-09-01 : Automatic System Reset Time
Define the time and date the system should automatically reset. This option is available
through either telephone programming or WebPro access.
➻92-06-01: Fill Extension Data
Enter the 4-digit program number you would like to fill. For example, Program 11-02 would
be entered as "1102". Enter the source extension number (the extension which contains the
data to be used) and press HOLD. Next, enter the first extension number to be filled and press
HOLD. Enter the last extension number to be filled and press HOLD. The data from the
source extension for that program will then be entered into the range of extensions defined.
➻92-07-01 : Delete Port Data
Enter the 4-digit program number you would like to delete. For example, Program 11-02
would be entered as "1102". Enter the first port number to be deleted and press HOLD. Enter
the last port number to be deleted and press HOLD. The data for that program will then be
erased for the range of ports defined.