Program 10 : System Configuration Setup
10-03 : PCB Setup
Aspire Software Manual Programming ◆733
For T1 Unit
For VMSU Unit
For VOIPU Unit
Physical Port Number 01-32
Item
No. Item Input Data Default
01 Logical Port Number 0-200 0
02 Frame Type Setup 0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame) 0
03 Zero Code Suppression Setup
ZCS_B8ZS 0 = B8ZS
1 = AMI/ZCS 0
04 DTI<->CSU Distance Setup 0= 0 feet – 133 feet
1= 133 feet – 266 feet
2= 266 feet – 399 feet
3= 399 feet – 533 feet
4= 533 feet – 655 feet
0
05 T1 Clock Source Master/Slave 0 = Internal
1 = External 1
Prior to 2.65 = 0
Item
No. Item Input Data Default
01 Logical Port Number Through Software 3.07: 0-256
From Software 4.0E+: 0-384 0
Physical Port Number 01-32
Item
No. Item Input Data Default
01 Trunk Logical Port Number 0-200 0
02 H.323 or SIP Trunk
Determine the IP trunk type setup.
Contact Your NEC Sales Representative
for information on the SIP feature
availability.
0 = H.323
1 = SIP 0