Program 81 : Basic Hardware Setup for Trunk
81-03 : 4TLIU Initial Data Setup
1402 Programming Aspire Software Manual
81-03 : 4TLIU Initial Data Setup
Description
Use Program 81-03 : 4TLIU Initial Data Setup to dene the various basic timers for the E&M tie
line PCB.
Input Data
Level: Aspire S Aspire M/L/XL
MF • Available. • Available.
Item No. Item Input Data Default
01 Companding method type 0 = u-law
1 = A-law 0 (u-law)
02 Answer Signal Time 1-255 (4-1020mS) 6 (60ms)
03 Clear Signal (Open Loop) Detection Time 1-255 (100-25500mS) 7 (700ms)
04 Ringing Signal Detection Min. Time 1-255 (8-20240mS) 10 (100ms)
05 Ringing Signal Stop Detection Time 1-255 (100-25500mS) 7 (700ms)
06 Hook Flash Time 1-255 (8-20240mS) 20 (200ms)
07 Pause Time 1-255 (1-255Sec) 50 (3000ms)
08 WINK/DELAY Duration Time 1-255 (8-20240mS) 20 (200ms)
09 Incoming-WINK/DELAY Send Time 1-255 (100-25500mS) 3 (300ms)
10 Seizure-WINK/DELAY Receive Max. Time 1-255 (100-25500mS) 48 (4800ms)
11 Receive WINK/DELAY Duration Min. Time 1-255 (8-20240mS) 13 (130ms)
12 Receive WINK/DELAY Duration Max. Time 1-255 (8-20240mS) 31 (310ms)
13 Receive DP Make Min. Time 1-255 (4-1020mS) 5 (10ms)
14 Receive DP Make Max. Time 1-255 (4-1020mS) 50 (100ms)
15 Receive DP Break Min. Time 1-255 (4-1020mS) 5 (10ms)
16 Receive DP Break Max. Time 1-255 (4-1020mS) 50 (100ms)
17 Pause Time After WINK/DELAY Receive 1-255 (8-20240mS) 13 (104ms)
18 Loop Off Guard Time 0-255 (0,100-25500mS) 20 (2000ms)
19 DP Break Time (10pps) 1-255 (4-1020mS) 32 (64ms)
20 DP Make Time (10pps) 1-255 (4-1020mS) 16 (32ms)
21 DP Inter-Digit Time (10pps) 1-255 (100-25500mS) 19 (608ms)
22 DP Break Time (0pps) 1-255 (4-1020mS) 16 (32ms)
23 DP Make Time (20pps) 1-255 (4-1020mS) 8 (16ms)
24 DP Inter-Digit Time (20pps) 1-255 (100-25500mS) 16 (512ms)