Program 82 : Basic Hardware Setup for Extension
82-06 : ISDN BRI & PRI Layer 3 (S-Point) Timer Setup1426 ◆Programming Aspire Software Manual
82-06 : ISDN BRI & PRI Layer 3 (S-Point) Timer Setup
Description
Use Program 82-06 : ISDN BRI & PRI Layer 3 (S-Point) Timer Setup to define the various
basic timers for layer 3 of ISDN BRI/PRI S-Point (defined in Program 10-03-04).
Input Data
Conditions
None
Level: Aspire S Aspire M/L/XL
IN • Available. • Available.
Layer 3 Timer Type Number 1-5
Item No. Item Input Data Default
01 T301 0,180-254 (sec) 180 (sec)
02 T302 1-254 (sec) 10 (sec)
03 T303 1-254 (sec) 4 (sec)
04 T304 0-254 (sec) 20 (sec)
05 T305 1-254 (sec) 30 (sec)
06 T306 0-254 (sec) 30 (sec)
07 T307 1-254 (sec) 180 (sec)
08 T308 1-254 (sec) 4 (sec)
09 T309 1-254 (sec) 90 (sec)
10 T310 0-180 (sec) 30 (sec)
11 T312 1-254 (sec) 6 (sec)
12 T313 1-254 (sec) 4 (sec)
13 T314 1-254 (sec) 4 (sec)
14 T316 (T317+1)-254 (sec) 120 (sec)
15 T317 1-(T316-1) 60 (sec)
16 T318 1-254 (sec) 4 (sec)
17 T319 1-254 (sec) 4 (sec)
18 T320 1-254 (sec) 30 (sec)
19 T321 1-254 (sec) 30 (sec)
20 T322 1-254 (sec) 4 (sec)