Program 84 : Hardware Setup for VoIP
84-02 : H.225, H.245 Information Basic Setup
Aspire Software Manual Programming 1445
84-02 : H.225, H.245 Information Basic Setup
Description
Use Program 84-02 : H.225, H.245 Information Basic Setup to dene the data of H.225 and
H.245.
It is recommended that these settings are left at the default values unless you are advised to change
the values by NEC Infrontia.
Input Data
Level: Aspire S Aspire M/L/XL
IN • Available. • Available.
Item
No. Item Input Data Default Description
01 H.225 Alerting Timer 0-255 sec 180 sec
02 H.225 Setup Acknowledge Timer 0-255 sec 9 sec
03 H.225 Setup Timer 0-255 sec 4 sec
04 H.225 Info Ack Timer 0-255 sec 9 sec
05 H.225 Call Proceeding Timer 0-255 sec 10 sec
06 -- Not Used --
07 H.245 Master Slave Determination Timer 0-255 sec 5 sec
08 H.245 Master Slave Determination Retry
Count 0-255 sec 3 sec
09 H.245 Capability Exchange Timer 0-255 sec 5 sec
10 H.245 Logical Channel Establishment
Timer 0-255 sec 50 sec Unidirectional or bi-directional logi-
cal channel establishment timer
11 H.245 Mode Request Procedures Timer 0-255 sec 50 sec
12 H.245 Close Logical Channel Timer 0-255 sec 50 sec
13 H.245 Round Trip Delay Timer 0-255 sec 50 sec
14 H.245 Maintenance Loop 0-255 sec 50 sec
15 RAS GRQ Timer 0-255 sec 5 sec
16 GRQ Retry Count 0-255 2
17 RAS RRQ Timer 0-255 sec 5 sec
18 RRQ Retry Count 0-255 3
19 RAS URQ Timer 0-255 sec 3