Program 84 : Hardware Setup for VoIP
84-18 : VOIPU Echo Canceller Control Setup1482 ◆Programming Aspire Software Manual
84-18 : VOIPU Echo Canceller Control Setup
Description
Use Program 84-18 : VOIPU Echo Canceller Control Setup to set the advanced Echo Canceller
functions for the VOIPU PCB. This function supports the following features:
●Supports long echo tail size (max. 128 msec)
●Adds adjustment parameters for echo cancellation
Input Data
Conditions
This program will not be displayed in PCPro until signing in with the MF level password.
Feature Cross Reference
●VoIP
Level: Aspire S Aspire M/L/XL
MF • Available. • Available with software 1.18+. Requires
VOIPU PCB firmware 3.2+.
Item No. Item Input Data Default
01 NLP Level Configuration 0 = Off
1 = On 0 (Off)
02 Coeff Control 0 = Keep
1 = Reset 0 (Keep)
03 Auto Update Control 0 = On
1 = Off 0 (On)
04 Search Freeze Control 0 = Freeze
1 = Execute 1 (Execute)
05 (Debug) MIPS Agent Control 0 = Execute
1 = Freeze 0 (Execute)