Program 84 : Hardware Setup for VoIP
84-18 : VOIPU Echo Canceller Control Setup
1482 Programming Aspire Software Manual
84-18 : VOIPU Echo Canceller Control Setup
Description
Use Program 84-18 : VOIPU Echo Canceller Control Setup to set the advanced Echo Canceller
functions for the VOIPU PCB. This function supports the following features:
Supports long echo tail size (max. 128 msec)
Adds adjustment parameters for echo cancellation
Input Data
Conditions
This program will not be displayed in PCPro until signing in with the MF level password.
Feature Cross Reference
VoIP
Level: Aspire S Aspire M/L/XL
MF Available. Available with software 1.18+. Requires
VOIPU PCB rmware 3.2+.
Item No. Item Input Data Default
01 NLP Level Conguration 0 = Off
1 = On 0 (Off)
02 Coeff Control 0 = Keep
1 = Reset 0 (Keep)
03 Auto Update Control 0 = On
1 = Off 0 (On)
04 Search Freeze Control 0 = Freeze
1 = Execute 1 (Execute)
05 (Debug) MIPS Agent Control 0 = Execute
1 = Freeze 0 (Execute)