Program 80 : Basic Hardware Setup for System
80-04 : Call Progress Tone Detector Setup
1392 Programming Aspire Software Manual
80-04 : Call Progress Tone Detector Setup
Description
Use Program 80-04 : Call Progress Tone Detector Setup to dene the various levels and timers
for the Call Progress Tone Detector
Input Data
Level: Aspire S Aspire M/L/XL
MF • Available. • Available.
Tone Detector Type No 1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = - Reserve -
5 = - Reserve -
Item No. Item Input Data
01 Detect Level 0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
02 Min. detect level 0-15
detect level 0 : –15dBm(0) to –30dBm(15)
detect level 1 : –30dBm(0) to –45dBm(15)
detect level 2 : –40dBm(0) to –55dBm(15)
03 S/N ratio 0-4 (0dB ~ -20dB)
04 No tone time 1-255 (30+30-7650ms)
(0 = No detection)
05 Pulse Count 1-255
06 ON min. time 1-255 (30+30-7650ms)
07 ON max. time 0-255 (30+30-7650ms)
(0 = No detection)
08 OFF min. time 1-255 (30+30-7650ms)
09 OFF max. time 1-255 (30+30-7650ms)
(0 = No detection)
10 -- Reserve -- 0-8
11 -- Reserve -- 0-8