Central Office Calls, Placing
Aspire Software Manual Features 219
Conditions
(A.) The system provides analog trunk CO service via COIU PCBs. COIU PCBs can connect to
either loop start or ground start CO lines. Refer to the system hardware manual for additional
details.
(B.) Analog Trunk (COIU) PCBs do not require circuit type programming.
Default Setting
Enabled.
Programming
10-03-03 : PCB Setup, For SLIU Unit - Transmit CODEC Gain Type
10-03-04 : PCB Setup, For SLIU Unit - Receive CODEC Gain Type
Customize the transmit and receive levels of the CODEC Gain Types for 500/2500 type single
line telephones.
11-01-01 : System Numbering
Set up a Service Code for Alternate Trunk Route Access.
11-09-01 : Trunk Access Code
If required, change the single-digit Trunk Access Code (normally 9). If you change this code,
you must also review the settings in 11-01 for the new code selected.
11-09-02 : Trunk Access Code - Alternate Trunk Route Access Code
Assign the Service Code set up in 11-01 for Alternate Trunk Route Access.
11-10-27 : Service Code Setup (for System Administrator) - Trunk Port Disable
Dene the service code which should be used by an extension user to block a trunk from
being used for outgoing calls (Default: 145).
11-11-13 : Service Code Setup (for Setup/Entry Operation) - Display Language Selection
for Keyset
Select the service code which can be used at an extension to change the displayed language on
a keyset’s display (default: 178).
11-12-01 : Service Code Setup (for Service Access)
To simplify placing calls, assign function keys for placing trunk calls: Trunk Group Routing/dial 9
keys (code 804).
14-01-01 : Basic Trunk Data Setup - Trunk Name
To make identifying calls easier, assign a name to each trunk.
14-01-02 : Basic Trunk Data Setup - Transmit CODEC Gain Type
14-01-03 : Basic Trunk Data Setup - Receive CODEC Gain Type
Assign a CODEC Gain Type to each trunk. This sets the amount of gain (amplication) for the
selected trunk.
14-01-07 : Basic Trunk Data Setup - Outgoing Calls
For each trunk, allow (1) or prevent (0) outgoing calls.
14-01-10 : Basic Trunk Data Setup - DTMF Tones for Outgoing Calls
For each trunk, enable (1) or disable (0) DTMF tones for outgoing trunk calls.
14-02-05 : Analog Trunk Data Setup - Dial Tone Detection for Directly Accessed Trunk
Use this option enable (1) or disable (0) dial tone detection for directly accessed trunks. If dis-
abled, the system outdials on the trunks without monitoring for dial tone.