Program 81 : Basic Hardware Setup for Trunk
81-08 : T1 Trunk Timer Setup
Aspire Software Manual Programming ◆1413
54 OPX - Receive Hookflash Duration Minimum Time 1-255 (100msec - 25500msec) 3 (300msec)
55 OPX - Receive Hookflash Duration Maximum Time 1-255 (100msec - 25500msec) 6 (600msec)
56 Loop - Loop Off Guard Time 1-255 (100msec - 25500msec) 20 (2000msec)
57 Ground - Loop Off Guard Time 1-255 (100msec - 25500msec) 20 (2000msec)
58 DID - Loop Off Guard Time 1-255 (100msec - 25500msec) 20 (2000msec)
59 E&M - Loop Off Guard Time 1-255 (100msec - 25500msec) 20 (2000msec)
60 OPX - Loop Off Guard Time 1-255 (100msec - 25500msec) 20 (2000msec)
61 OPX - Double Ringing Send Time 1 1-255 (100msec - 25500msec) 5 (500msec)
62 OPX - Double Between Ringing Send Time 1 1-255 (100msec - 25500msec) 5 (500msec)
63 OPX - Double Ringing Send Time 2 1-255 (100msec - 25500msec) 25 (2500msec)
64 OPX - Double Between Ringing Send Time 2 1-255 (100msec - 25500msec) 30 (3000msec)
65 OPX - Single Ringing Send Time 1 1-255 (100msec - 25500msec) 10 (1000msec)
66 OPX - Single Between Ringing Send Time 1 1-255 (100msec - 25500msec) 9 (900msec)
67 Loop - Guard Time 1 1-255 (100msec - 25500msec) 9 (900msec)
68 Ground - Guard Time 1 1-255 (100msec - 25500msec) 9 (900msec)
69 DID - Guard Time 1 1-255 (100msec - 25500msec) 9 (900msec)
70 E&M - Guard Time 1 1-255 (100msec - 25500msec) 9 (900msec)
71 OPX - Guard Time 1 1-255 (100msec - 25500msec) 9 (900msec)
72 All - Guard Time 2 1-250 (4msec - 1020msec) 3 (12msec)
73 All - Dial Sending Complete time 1-255 (100msec - 25500msec) 20 (2000msec)
74 All - On-Hook Bit Send Time 1-255 (100msec - 25500msec) 40 (4000msec)
75 Loop - Open Loop Time 1-255 (100msec - 25500msec) 6 (600msec)
76 Ground - Open Loop Time 1-255 (100msec - 25500msec) 6 (600msec)
77 DID - Open Loop Time 1-255 (100msec - 25500msec) 6 (600msec)
78 E&M - Open Loop Time 1-255 (100msec - 25500msec) 6 (600msec)
79 OPX - Open Loop Time 1-255 (100msec - 25500msec) 6 (600msec)
80 Loop - Close Loop Time 1-250 (4msec - 1020msec) 13 (52msec)
81 DID - Close Loop Time 1-250 (4msec - 1020msec) 13 (52msec)
82 Ground Loop - Close Loop Time 1-250 (4msec - 1020msec) 13 (52msec)
Item No. Item Input Data Default