Central Office Calls, Answering
Aspire Software Manual Features ◆209
CODEC Filter Data Setup Program Added
When Program 81-07-01 : CODEC Filter Setup for Analog Trunk Ports is set to "4 - Specified
Data", the system will use the settings in Program 81-09 : COIU CODEC Filter Data Setup.
These values should not be changed from their default settings unless directed by NEC’S Technical
Service department.
The side tone of the COIU is adjusted using all 16 values, however, special software is required
in order to compute these values. The setting is not proportional to the gain level. To change
these values, contact NEC’s Technical Service department for assistance.
Sidetone Volume Setup
A new option has been added to allow the system programming for the keyset side tone volume.
There are two levels, based on whether the connected trunk is a digital trunk or analog trunk.
Flexible Ringing by Caller ID
The Flexible Ringing by Caller ID feature provides several different options for rerouting calls
based on the Caller ID received.
●Reject/Reroute "Private" Caller ID Calls
When an analog or ISDN trunk call is received with “Private” Caller ID information, the sys-
tem can reject the call by playing a VRS message or it can route the call to an alternative
extension or incoming ring group programmed in Program 22-18-01.
●Reject/Reroute Based on Entry in ABB Table
When an analog, ISDN or IP trunk call is received with regular Caller ID information, the sys-
tem can reject the call by playing a VRS message if the Caller ID number matches the ABB
group number programmed in Program 22-16-01 and ABB entry in Programs 13-02-01 and
13-04-01.
The analog, ISDN or IP trunk call can also be routed to an alternative extension or incoming
ring group if the Caller ID number matches the common ABB table (Program 13-04).
Programming Examples for Flexible Ringing by Caller ID:
●To refuse the “Private” Caller ID incoming call:
Program 14-01-27: 1 (reject)
Program 22-18-01: 0 (no transfer)
Program 40-10-06: 2 (VRS message 2)
Then turn on the Private Call Refuse mode using the service code (Program 11-10-32) or Pro-
grammable Function Key (code 86).
●To transfer the “Private” Caller ID incoming call to extension 301 as ring pattern 2:
Program 14-01-27: 1 (reject)
Program 22-18-01: 1 (extension number)
Program 22-18-02: 301 (extension 301)
Program 22-18-03: 2 (ring pattern 2)
Then turn on the Private Call Refuse mode using the service code (Program 11-10-32) or Pro-
grammable Function Key (code 86).