Program 81 : Basic Hardware Setup for Trunk
81-08 : T1 Trunk Timer Setup
Aspire Software Manual Programming 1411
81-08 : T1 Trunk Timer Setup
Description
Use Program 81-08 : T1 Trunk Timer Setup to dene the various basic timers for each T1 trunk
type.
Input Data
Level: Aspire S Aspire M/L/XL
IN • Available. • Available.
Layer 3 Timer Type Number 1-5
Item No. Item Input Data Default
01 Loop - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
02 Ground - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
03 DID - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
04 E&M - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
05 OPX - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
06 Loop - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
07 Ground - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
08 DID - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
09 E&M - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
10 OPX - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
11 Loop - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
12 Ground - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
13 DID - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
14 E&M - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
15 OPX - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
16 Loop - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
17 Ground - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
18 DID - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
19 E&M - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
20 OPX - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
21 Loop - Loop Current Detection Time 1-250 (4msec - 1020msec) 40 (200msec)
22 Ground - Loop Current Detection Time 1-250 (4msec - 1020msec) 40 (200msec)
23 DID - Loop Current Detection Time 1-250 (4msec - 1020msec) 40 (200msec)