Program 82 : Basic Hardware Setup for Extension
82-04 : SLIU Initial Data Setup
1422 Programming Aspire Software Manual
82-04 : SLIU Initial Data Setup
Description
Use Program 82-04 : SLIU Initial Data Setup to dene the various basic timers for the ASTU
PCB.
Input Data
Conditions
This program will not be displayed in PCPro until signing in with the MF level password.
Feature Cross Reference
None
Level: Aspire S Aspire M/L/XL
MF • Available. • Available.
Item No. Item Input Data Default
01 Companding method type 0 = u-law
1 = A-law 0 (u-law)
02 Ringing frequency 0 = 25Hz
1 = 20Hz
2 = 16Hz
2 (16Hz)
03 Minimum break time 1-255 (5ms-1275ms) 2 (10ms)
04 Maximum break time 1-255 (5ms-1275ms) 20 (100ms)
05 Minimum make time 1-255 (5ms-1275ms) 2 (10ms)
06 Maximum make time 1-255 (5ms-1275ms) 20 (100ms)
07 Minimum hook ash time 1-255 (5ms-1275ms) 21 (105ms)
08 Maximum hook ash time 1-255 (5ms-1275ms) 200 (1000ms)
09 Minimum ground ash time 1-255 (5ms-1275ms) 21 (105ms)
10 Minimum off-hook time 1-255 (5ms-1275ms) 21 (105ms)
11 No detection time after off-hook 1-255 (5ms-1275ms) 60 (300ms)
12 No detection time after pulse dial detection 1-255 (5ms-1275ms) 70 (350ms)
13 Loop disconnect time, Reversal time 1-255 (10ms-2550ms) 60 (600ms)
14 Ring, Message wait period time 1-255 (5ms-1275ms) 150 (750ms)