Night Service
444 ◆Features Aspire Software Manual
Programmable Function Key Can Toggle Night Modes
The software allows a Night Service Programmable Function Key (PGM 15-07 or SC 851: 09 + 0)
to toggle night modes. You can determine in programming how many modes through which the
user will toggle. Note that the additional data for the Programmable Function Key must be set to
"0" for the toggle function to work.
Conditions
(A.) The NTCPU PCB has connections for a Night Mode switch. During installation, you connect
a mechanical switch to these contacts to provide an additional method of Night Mode switch-
ing. Refer to the system hardware manual for additional details.
(B.) If the Night Mode Relay is connected and there is any voltage present (pins 2 and 7 on the
NTCPU’s CN17 connector), the night mode cannot be toggled using the Night Mode
Programmable Function Keys.
(C.) The following programs are affected by Night Mode:
(D.) Almost all features are affected by Night Mode except for the following:
●Dial Tone Detection
●External Alarm Sensors
●Flexible System Numbering
●Labelmaker
●Pulse to Tone conversion
●SMDR
●Volume Control
(E.) Multiple Directory Number (virtual extension) keys do not support Day/Night Mode (09) Program-
mable Function keys.
Default Setting
System is always in the Day Mode.
Programming
➻10-05-01 : General Purpose Relay Setup
Define which relay circuits (5-8) on the 2PGDAD adapter are used for General Purpose
Relays.
➻10-21-01 : NTCPU Hardware Setup, External Source Control Switch Selection
Specify the function of the relay switch for the external tone source control (0=External MOH
source, 1=BGM source, 2=External Speaker, 3=General Purpose Relay).
➻11-10-01 : Service Code Setup (for System Administrator) - Day / Night Mode Switching
Customize the service code (818) to be used for day/night mode switching.