Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Aspire Software Manual Programming 1407
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to dene the various
basic timers for layer 3 of ISDN BRI/PRI (dened in Program 10-03-04).
Input Data
Level: Aspire S Aspire M/L/XL
MF • Available. • Available.
Layer 3 Timer Type Number 1-5
Item No. Item Input Data Default
01 T301 0,180-254(sec) 180(sec)
02 T302 1-254(sec) 15(sec)
03 T303 1-254(sec) 4(sec)
04 T304 0-254(sec) 30(sec)
05 T305 1-254(sec) 30(sec)
06 T306 0-254(sec) 30(sec)
07 T307 1-254(sec) 180(sec)
08 T308 1-254(sec) 4(sec)
09 T309 1-254(sec) 90(sec)
10 T310 0-180(sec) 180(sec)
11 T312 1-254(sec) 6(sec)
12 T313 1-254(sec) 4(sec)
13 T314 1-254(sec) 4(sec)
14 T316 (T317+1)-254(sec) 120(sec)
15 T317 1-(T316-1) 60(sec)
16 T318 1-254(sec) 4(sec)
17 T319 1-254(sec) 4(sec)
18 T320 1-254(sec) 30(sec)
19 T321 1-254(sec) 30(sec)
20 T322 1-254(sec) 4(sec)