Program 10 : System Conguration Setup
10-03 : PCB Setup
726 Programming Aspire Software Manual
Input Data
For ESIU Unit
Physical Port Number Through Software 3.07: 01-16
From Software 4.0E+: 01-32
B-Channel 1
Item
No. Item Input Data Default
01 Terminal Type 0 = Not set
1 = Keyset/DSLT
2 = SLT Adapter
3 = -- Not used --
4 = -- Not used --
5 = -- Not used --
6 = PGD (Paging)
7 = PGD (Tone Ringer)
8 = PGD (Doorbox)
9 = PGD (ACI)
10 = DSS Console
11 = -- Not used --
0
02 Logical Port Number 0 = Not set
1 = Keyset
2 = SLT Adapter
3 = Not used
4 = Not used
5 = 2DCI Adapter 1 - 32
6 = PGD (Paging)
7 = PGD (for Tone Ringer) 1-4 or 1-8
8 = PGD (for Door Box) 1-4 or 1-8
9 = PGD (for Analog I/F) 1-8 or 1-96
10 = DSS
11 = Not used
0
03 Additional Data This option is reserved for future use.
3 = Not used
4 = Not used
01-16 (port number) A port number is automatically set as
the order which the terminal started.
0
04 Optional Installed Unit 1 0 = none
1 = APR Module
2 = APA Module
3 = ADA Module
4 = CTA Module
5 = CTU Module
0