Program 15 : Extension, Basic Setup
15-02 : Multi-Line Telephone Basic Data Setup
904 Programming Aspire Software Manual
19 CTA/CTU Data Communication
Mode
Select ‘0’ if the dip switch settings on
the CTA/CTU Adapter are set to PC
connection (1=on, 2-8=off) or select
‘1’ if the dip switches are set to printer
connection (1-2=on, 3-8=off).
0 = CTI mode
1 = non-procedural/SMDR
mode
0 15-02-20
20 Baud rate for CTA Port
Select the baud rate to be used by the
CTA Adapter.
0 = 4800
1 = 9600
2 = 19200
2 15-02-19
21 Virtual Extension Access Mode
(when idle Virtual Extension key
pressed)
Determine whether an extension’s Vir-
tual Extension/Call Coverage Key
should be as a DSS key to the exten-
sion and for receiving calls (0), for
placing and receiving calls (1),or just
receiving incoming calls (2).
0 = DSS (Inbound/Outbound)
1 = Outgoing
2 = Ignore Key (Inbound)
2
22 Multiple Incoming From Intercom
and Trunk
If enabled, this affects how a Hotline
key lamps, based on the setting in Pro-
gram 22-01-01. If set to 1 for trunk
priority, the Hotline key will lamp
solid when a trunk call rings in. If set
to 0 for intercom priority, the Hotline
key will not lamp for incoming trunk
calls, but will lamp solid for intercom
calls.
If this option is disabled, Hotline keys
will lamp solid for any incoming calls
regardless of the setting in Program
22-01-01.
0 = Disable
1 = Enable 1 22-01-01
Item
No. Item Input Data Default Related
Program