Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
1398 ◆Programming Aspire Software Manual
Conditions
This program will not be displayed in PCPro until signing in with the MF level password.
Feature Cross Reference
●Central Office Calls, Placing
14 Flash (Hooking 1)
This sets the flash (Hooking 1) duration for analog trunk calls. See Pro-
gram 14-02-04.
1-255 (16-4080mS) 50 (800ms)
15 Flash (Hooking 2)
This sets the flash (Hooking 2) duration for analog trunk calls. See Pro-
gram 14-02-04.
1-255 (16-4080mS) 156 (2496ms)
16 Pause Time 1-255 (16-4080mS) 16 (1024ms)
17 PFT Idle Detection Time 1-255 (64-16320mS) 47 (3008ms)
18 Grounding Start Time 1-255 (8-2040mS) 6 (48ms)
19 Grounding Start Give-Up Time 1-255 (64-16320mS) 47 (3008ms)
20 Loop Reverse Detect Minimum Time 1-255 (8-2040mS) 13 (104ms)
21 Loop Reverse Detect Maximum Time 1-255 (8-2040mS) 107 (856ms)
22 Loop Disconnect Detect Minimum Time 1-255 (8-2040mS) 50 (400ms)
23 Loop Disconnect Detect Maximum Time 1-255 (8-2040mS) 80 (640ms)
24 On Hook Normal Detect Time 1-255 (8-2040mS) 3 (24ms)
25 On Hook Reverse Detect Time 1-255 (8-2040mS) 2 (16ms)
26 On Hook Disconnect Detect Time 1-255 (16-4080mS) 188 (3008ms)
27 Pulse Dial Break Time (10pps) 1-255 (4-1020mS) 8 (32ms)
28 Pulse Dial Make Time (10pps) 1-255 (4-1020mS) 4 (16ms)
29 Inter-Digit Time (10pps) 1-255 (32-8160mS) 19 (608ms)
30 Pulse Dial Break Time (20pps) 1-255 (4-1020mS) 4 (16ms)
31 Pulse Dial Make Time (20pps) 1-255 (4-1020mS) 2 (8ms)
32 Inter-Digit Time (20pps) 1-255 (32-8160mS) 16 (512ms)
33 Charging Pulse Minimum Duration Time 1-255 (8-2040mS) 9 (72ms)
34 Charging Pulse Minimum Period Time 1-255 (8-2040mS) 29 (232ms)
35 Charging Pulse Minimum Interval Time 1-255 (8-2040mS) 6 (48ms)
Item
No. Item Input Data Default