Program 25 : VRS/DISA Setup
25-13 : System Option for DISA
Aspire Software Manual Programming 1139
25-13 : System Option for DISA
Description
Use Program 25-13 : System Option for DISA to enter the password DISA callers must dial
before the system will allow them to record, listen to and or erase the VRS messages. This program
also is used to dene additional DISA call options.
Input Data
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
Voice Response System (VRS)
Level: Aspire S Aspire M/L/XL
IN • Available. • Available.
Item No. Item Input Data Default
01 VRS Password
Enter the password DISA callers must dial before the system will
allow them to record, listen to and or erase the VAU messages.
1-9, 0, *, #
6 digits xed No setting
02 Continue Code for DISA Trunk to Trunk
With software through 2.68, program the Continue code. This code is
used with the Warning Tone for Long Conversation for DISA callers.
This allows the user to press the programmed code to continue the
conversation the call. If the Continue code is entered, this resets the
timer in Program 25-07-07.
With software 4.0E+, use Program 20-28-01.
1-9, 0, *, #
1 digit
03 Disconnect Code for DISA Trunk to Trunk
With software through 2.68, program the Disconnect code. This code
is used with the Warning Tone for Long Conversation for DISA call-
ers. This allows the user to press the programmed code to disconnect
the call. If the Disconnect code is entered, the call is disconnected
immediately.
With software 4.0E+, use Program 20-28-02.
1-9, 0, *, #
1 digit