Program 15 : Extension, Basic Setup
15-16 : SIP Register ID Setup for Extension
942 Programming Aspire Software Manual
15-16 : SIP Register ID Setup for Extension
Description
Use Program 15-16 : SIP Register ID Setup for Extension to set the SIP Register ID to an exten-
sion port. If both 14-12 and 15-16 are assigned, then the system uses the data in Program 15-16.
Register ID 0 is associated with Program 10-28 and 10-29 data. Other registered IDs (1-31) are
associated with Program 10-36 data.
Contact Your NEC Sales Representative for information on the SIP feature availability.
Input Data
Conditions
None
Feature Cross Reference
VoIP
Level: Aspire S Aspire M/L/XL
IN • Available. • Available.
Extension Number Max. 8 digits
Item No. Item Entries Default Related
Program
01 SIP Register ID Setup for
Extension
Set the SIP Register ID to an
extension port.
0-31 0 10-28
10-29
10-36
14-12