VoIP
682 Features Aspire Software Manual

Fax Relay

Required Items
16VOIPU PCB
G3 Fax equipment (G4 Fax is not supported)
Basic Programming
All VOIPU programming required for the feature as well as the following:
15-03-03 : Single Line Telephone Basic Data Setup
Set the terminal type to “1” (Special Terminal) for the extension which has the fax connected.
84-01-59 : CODEC Information Basic Setup - Fax Relay Function
Enable (1) or disable (0) the Fax Relay function for the system.
When the voice CODEC to be used in a session is selected as G.711, fax signals may
be sent even when this option is disabled. This occurs as G.711 sends fax signals in voice
packets. Frequent packet loss on the network may cause the session to disconnect since the
connection is not established as a Fax Relay (T.38). To avoid this, set Program 84-01-33 to
a CODEC other than G.711 and the fax connection will then be established as T.38 (Fax
Relay).
84-01-36 through 84-01-58 : CODEC Information Basic Setup
These programs are also available for the Fax Relay feature, but it is recommended that they
remain at the system default.
The following fax machines require changes as noted below:
NEFAX-490:
Set the VOIPU ECM to off (Program 84-01-55 = 0) for transmission on the VOIPU. The
NEFAX-490 must also have the ECM turned off and the auto-answer alerting time should be
increased.
NEFAX-500:
The NEFAX-500 must have the ECM set to off.

Firmware Download for Aspire Keyset with IP Adapter

There are two types of downloads: Local (Aspire Keyset with IP Adapter) and Center (System).
When you select Center download, you need to set the hardware version and rmware version. If
the hardware version is the same and the rmware version is different, then the download will start.
A TFTP server or FTP server is required.
Programming
84-07-01 : Firmware Download Setup - Server Mode
Select the server mode (0=TFTP, 1=FTP).
84-07-02 : Firmware Download Setup - File Server
Enter the IP address for the le server.
84-07-03 : Firmware Download Setup - Log-In Name
Enter the log-in name to be used, up to 20 characters.
84-07-04 : Firmware Download Setup - Password
Enter the password to be used, up to 20 characters.
84-08-01 : Firmware Name Setup - Firmware Directory
Enter the rmware directory to be used, up to 64 characters maximum.