Installation and initial configuration of an IP Telephony node Page 315 of 910
IP Line Description, Installation and Maintenance
Note: EMC restriction must be considered when installing the Voice
Gateway Media Cards. For more information, see “Electro-Magnetic
Containment” on page 897.

Installing and cabling the ITG-P 24-port line card

Each ITG-P 24-port line card requires two slots in the CS 1000 or Meridian 1.
Only the left slot of the card connects to the IPE backplane and I/O panel.
A maximum of eight ITG-P 24-port line cards can be installed in an IPE shelf
in a Large System. The ITG-P 24-port line card can occupy any two adjacent
slots in an IPE shelf, with the left slot of the card plugging into slots 0 to 6
and 8 to 15. The left slot of an ITG-P 24-port line card cannot be plugged into
slot 7, because the XPEC card is situated between slots 7 and 8.
To enable a module to hold the maximum number of ITG-P 24-port line
cards, install each card with the left slot of the card inserted into an
even-numbered slot.
To install an ITG-P 24-port line card, follow the steps in Procedure 14 on
page 316.
CAUTION WITH ESD DEVICES
Wear an ElectroStatic Discharge Strap (ESDS) when
handling ITG-P 24-port and Media Card line cards. As an
additional safety measure, handle all cards by the edges,
and when possible, with the loosened packaging material
still around the component.
WARNING
The CAT5 Ethernet cable between the ITG-P 24-port line
card TLAN network interface and the Layer 2 switch must
have a length of 50 meters or less for proper operation of
the TLAN network interface