Page 348 of 910 Installation and initial configuration of an IP Telephony node
553-3001-365 Standard 4.00 August 2005
Group maximums
Without FIBN, Package 365, there is a maximum of five network groups
available, 0 – 4. With Package 365, there are a maximum of eight network
groups, 0 – 7.
For normal traffic engineering, provision up to 1024 VTNs on a single virtual
superloop for a Large System/CS 1000E. For non-blocking, do not exceed
120 VTNs on a single virtual superloop for a Large System/CS 1000E.
Nortel recommends that virtual superloops are configured starting in the
highest non-physically equipped group available. Table 66 lists the prompts
and responses required to configure virtual superloops in LD 97.
Small Systems
In Small Systems, virtual superloops contend for the same range of
superloops, 96 – 112, with phantom superloops.
Up to 128 VTNs can be configured on a single virtual superloop for a
Meridian 1 Option 11C Cabinet and Option 11C Chassis system, for a
maximum of 640 VTNs in each system.
Table 66
LD 97 – Virtual superloop configuration for Large Systems /CS 1000E
Prompt Response Description
REQ CHG Change existing data.
TYPE SUPL Superloop
SUPL Vxxx V represents a virtual superloop and xxx is the number of
the virtual superloop where:
xxx = 0 – 156 and multiple of four for a Large System
without FIBN package 365
xxx = 0 – 252 and multiple of four for a Large System
with FIBN package 365