Administration Commands
define_qllc_port
Specifies the link station transmit/receive capability. Possible values are:
LS_TWS
LS_TWA
max_ifrm_rcvd
Maximum number of
target_pacing_count
Indicates the desired pacing window size. Specify a value in the range
max_send_btu_size
Maximum BTU size that can be sent from this port. This value is used to negotiate the maximum BTU size that a pair of link stations can use to communicate with each other. The value includes the length of the TH and RH (total 9 bytes), as well as the RU.
address
Local X.25 DTE address of the port. This address must match the address configured in your X.25 driver for this network.
Note
If no address is specified, an outgoing call request generated by SNAplus2 will not contain the X.25 calling address. Some hosts require this address as a security measure on incoming calls, and may not accept the connection without it.
implicit_cp_cp_sess_support
Specifies whether
YES
NO
implicit_limited_resource
Specifies whether implicit link stations off this port are defined as limited resources. Possible values are:
NO
Implicit links are not limited resources and are not automatically deactivated.
NO_SESSIONS
Implicit links are limited resources and are automatically deactivated when no active sessions are using them.
INACTIVITY
Implicit links are limited resources and are automatically deactivated when no active sessions are using them or when no data has flowed for the time period specified by the implicit_deact_timer parameter.
• If no
170