HP UX Internet and Networking Software manual Maxxidsize, Maxretrycount

Models: UX Internet and Networking Software

1 651
Download 651 pages 11.83 Kb
Page 206
Image 206

Administration Commands

define_sdlc_port

LEASED

Port is used by a leased line.

For a switched line used for outgoing calls (port_type is PORT_SWITCHED and inb_link_act_lim is 0), specify one of the following values:

SW_DIAL_AUTO

Automatic dial-out capabilities

SW_DIAL_MAN

Manual dial-out capabilities

For a switched line used for incoming calls (port_type is PORT_SWITCHED and out_link_act_lim is 0), specify one of the following values:

SW_ANSWER_AUTO

Automatic answer capabilities

SW_ANSWER_MAN

Manual answer capabilities

max_xid_size

The maximum size, in bytes, of an XID that will be sent or received on this link. This parameter helps minimize buffer usage. A safe absolute maximum is 256.

max_retry_count

Maximum number of times that a frame or group of frames can be retransmitted on this port before a problem is diagnosed. Most users set this value to 5.

opt1

Port options flag 1. Set this parameter to NONE to specify no options, or combine one or more of the follow- ing options with a + character to specify a value:

FOUR_WIRE

Specify this value when you have a 4-wire connection that is capable of sending data in both directions simultaneously. However, the connection may be half-duplex, because half-duplex is the most common mode of operation.

Do not specify this value when you have a 2-wire connection that can send data in only one direction at a time.

NRZI

Use NRZI serial encoding for transmitting data over the data link. This type of encoding works in the majority of cases; try it first if you are connecting to a new network. If you do not specify this option, NRZ serial encoding is used on this link.

If you are configuring a link to a network, use the encoding type that is used by the rest of the network. All stations on a network that communicate with each other must use the same encoding type. Neither type of encoding works for all situations. If you experience problems when using one type of encoding, change the encoding type for all stations to the other type.

FULL_DUPLEX

Specify this value if data is sent in both directions simultaneously. This setting requires a 4-wire physical line. You must set this option if either pri_fdplx or sec_fdplx is set to YES.

Do not specify this value if data is sent in only one direction at a time.

206

Page 206
Image 206
HP UX Internet and Networking Software manual Maxxidsize, Maxretrycount