![](/images/new-backgrounds/1308428/3084281245x1.webp)
Administration Commands
term_node
INVALID_PORT_NAME
The port_name parameter did not match the name of a defined port.
UNRECOGNIZED_DEACT_TYPE
The stop_type parameter was not set to a valid value.
State Check
If the command does not execute because of a state error, SNAplus2 returns the following parameters:
primary_rc
STATE_CHECK
secondary_rc
STOP_PORT_PENDING
The specified port is already being deactivated.
Other Conditions
If the command does not execute because other conditions exit, SNAplus2 returns the following parameters:
primary_rc
CANCELLED
secondary_rc
NO_SECONDARY_RC
The stop_type parameter specified an orderly stop, but the port was then stopped by a second command, specifying an immediate stop, or by a failure condition.
Appendix A, Common Return Codes from snapadmin Commands, lists combinations of primary and secondary return codes that are common to all commands.
2.209 term_node
The term_node command stops a node with a specified urgency and also stops all connectivity resources associated with the node.
If an RJE workstation is using LUs owned by the node, the workstation will not automatically stop when the node is stopped (unless the RJE workstation was started with the option that specifies that the RJE workstation should stop after n minutes of inactivity). If you did not specify the
This command must be issued to a running node.
2.209.1 Supplied Parameters
Parameter name | Type | Length | Default |
[term_node] |
|
|
|
stop_type | constant |
| SHUTDOWN |
Supplied parameters are:
stop_type
Specifies how SNAplus2 stops the node. Possible values are:
623